Shinwoo Electronics Co., Ltd., founded in 1989, specializes in gas safety systems and differentiates its products for home, industrial, and special-purpose applications. By developing control systems for gas, fire protection, security, and lighting—ranging from home networks to industrial sites—the company strives to ensure public safety and create a comfortable living environment. Its goal is to protect lives and property through the development of high-quality, multifunctional safety devices, operating under a management philosophy of delivering the best products, highest quality, and greatest service.
Based on years of accumulated technology and customer trust, Shinwoo Electronics is committed to achieving the highest level of customer satisfaction through thorough and rigorous quality control. With a mindset of continuous learning, the company focuses on new product development, world-class quality, and ultra-fast service, aiming to remain a leader in the safety device industry. Upholding the honor of the Shinwoo name and the spirit of craftsmanship, the company pledges to always do its best.
Thank you.
No. | Product Name | HS CODE |
1 | GAS SHUT OFF VALVE | 9027 |
2 | CONTROLLER | 8531 |
3 | GAS DETECTOR | 8481 |
4 | GAS ALARM | 8537 |
Product Description
An automatic fire extinguisher (hybrid) is a product consisting of a fire detector, a gas breaker to control gas valves, an electric switch to control electricity in an electric stove, a fire extinguisher to control fire extinguisher, and a fire extinguisher to prevent fire or gas leakage.
Residential Kitchen Automatic Fire Extinguishing System
Receiving part/ Control part
Through central processing units, detecting and inspecting devices control operating systems and shut off devices, and operate buzzers, display current status, check the pressure of fire extinguisher and the status of tube, and show the parts with trouble.
Classification | Type |
Voltage | AC 220V/60Hz |
Power consumption | 6.1W |
Redundant power supply | Ni-Cd Battery / DC 12V 600mAh |
Operation temperature range | -10 ~ 40℃ |
Specification(Communication) | Exterior Communication Module(RS-485, PLC) |
Function | Function display and remote control |
Operation temperature range | -10 ~ 40℃ |
S/W Type | TACT S/W |
Gas Detection part

When gas density gets over the alarm operating level, it sends gas leakage signal to the receiver, and turns on the alarm sound and alarm light
Classification | Type |
Voltage | DC 12~18V |
Gas type | LNG / LPG |
Gas density for alarm | Town gas(heavy), LPG : 600~4,500 PPMTown gas(light), LNG : 600~12,500 PPM |
Gas detecting type | Diffusion Type |
Gas sensory type | Combustible catalytic sensor |
Fire extinguisher

When fire occurs, with the working of operative device, the outlet of the fire extinguishing media is automatically open and it sprays the extinguishing media. This allows fire prevention early on.
Classification | Type | |
Spray Rate | Over 99% | |
Operating Method | Press Pin Pressing Type | |
Container | Material | STS 304 |
Thickness | 1t | |
Inner Volume | 830ml | |
Tube | Material | KS D 5301 C 1220 |
Thickness | 0.7mm | |
Full Diameter | ¢6.35 | |
Length | 900mm | |
Extinguishing media | Type | Loaded stream |
Charging Amount | 0.6ℓ | |
Release Outlet(nozzle) | Spraying Time(20℃) | 11 second |
Spraying Angle(20℃) | 76° | |
Nominal Fence Area | 690mm * 690mm | |
Effective Intallation Height | 500mm ~ 700mm | |
Shut off part
It can automatically open and close the gas valve with the control signal of receiver.
Model | SV-20B | SV-20H | SV-20E |
Size | 20A | INPUT 15,20A / OUTPUT15A | |
shut off method | Handle Operational | Valve Operational | Electric valve type |
Torque(Max) | 60kgf . Com | ||
shut off speed | Within 10seconds | 0.5 sec | |
Pressure in use | Low Pressure(0.1kg / ㎠) | ||
Durability | More than 6,000times | More than 60,000times | |
Operating control method | Motor Operation limit S/W method | Solenoid Method | |
How to open/close | Remote and Manual Open/Close method | ||
Spray nozzle / Temperature detection part

By checking the temperature around the gas range, it sends the data of electric change earned from temperature change to the central process unit of receiver. With the data of 1st temperature sensor, it detects or prevents the fire, and with the data of 2nd temperature sensor, it detects fire and controls the operation of operative devices.
Classification | Type | |
1st Temperature sensor | Type | Temperature sensor type, Restorable Type |
Operation temperature | 100℃ | |
Operation time | Within ‘0’second (Operation temperature 125%) | |
2nd Temperature sensor | Type | Temperature sensor type, Restorable Type |
Operation temperature | 139℃ | |
Operation time | Within ‘60’second (Operation temperature 125%) | |